Supplied by Bonna Indonesia and BOSSPIPE™

JACKSTRONG™ logo

JACKSTRONG™
GRP Lined Concrete Jacking Pipe

Empire Infrastructure supplies JACKSTRONG™ GRP lined concrete jacking pipe from DN900 to DN3000, combining the structural strength of reinforced concrete with the corrosion resistance of BOSSPIPE™ Glass Reinforced Plastic for pipe jacking and microtunnelling.

DN9003000
Diameter Range
Composite Build
Concrete with GRP
Long Drives
High Jacking Load Capacity

Why JACKSTRONG™

Two materials, one pipe

Structural Strength

The reinforced concrete outer structure carries the jacking load, giving high jacking load capacity for long drive performance.

Corrosion Resistance

The BOSSPIPE™ Glass Reinforced Plastic (GRP) inner liner gives corrosion resistance where the carried flow would attack unlined concrete.

Full Diameter Range

JACKSTRONG™ covers DN900 to DN3000 across a full range of diameters and ground conditions.

JACKSTRONG™ socket end detail

The Product

JACKSTRONG™
GRP lined concrete jacking pipe

JACKSTRONG™

JACKSTRONG™ is a GRP lined concrete jacking pipe engineered for pipe-jacking and microtunnelling applications. Combining the structural strength of Bonna’s reinforced concrete with the corrosion resistance of BOSSPIPE™ Glass Reinforced Plastic (GRP), JACKSTRONG™ delivers high jacking load capacity, corrosion resistance, and long-drive performance across a full range of diameters and ground conditions.

Empire supplies JACKSTRONG™ across Australia and New Zealand, with intermediate jacking station (IJS) units available to suit long drives.

For drive specific advice on diameter, liner specification, jacking load capacity and IJS configuration, contact Empire’s technical team.

DN900 to DN3000 Pipe jacking and microtunnelling Reinforced concrete with GRP liner Intermediate jacking stations available Bonna Indonesia and BOSSPIPE™
JACKSTRONG™ pipe loaded for transport

On the Drive

High jacking load.
Long drive performance.

JACKSTRONG™ combines a reinforced concrete outer structure with a BOSSPIPE™ GRP inner liner, for high jacking load capacity across a full range of diameters and ground conditions.

Request a Quote

Specifications

JACKSTRONG™ at a glance

The summary below is the specification as recorded for the JACKSTRONG™ range supplied by Empire. Detailed dimensional, jacking load and liner data is available from Empire’s technical team for your drive.

ParameterSpecification
Diameter RangeDN900 to DN3000
ConstructionComposite: reinforced concrete with GRP
Supplied byBonna Indonesia and BOSSPIPE™
JACKSTRONG™Pipe JackingMicrotunnellingGRP

Note: Confirm diameter, liner specification, jacking load capacity, joint detail and intermediate jacking station configuration with Empire’s technical team against your drive parameters. The contractor remains responsible for compliance with local regulations and for applying appropriate safety factors.

Datasheets, brochures and technical documents for JACKSTRONG™ are available to download in the Empire Engineer Portal. Go to the Engineer Portal

Applications

Where JACKSTRONG™
is used

The JACKSTRONG™ range supplied by Empire covers the following drive types and applications.

Pipe jackingConventional pipe jacking drives, including long drives.
MicrotunnellingRemote controlled microtunnel drives.
Gravity sewerSewer drives where the GRP liner provides corrosion resistance.
StormwaterStormwater drives and trunk drainage.
Intermediate jacking stationsIJS units available to suit drive length and jacking loads.

In the Field

JACKSTRONG™ in detail

JACKSTRONG™ GRP lined concrete jacking pipe
JACKSTRONG™ GRP lined concrete jacking pipe.
JACKSTRONG™ socket end detail
Socket end detail.
JACKSTRONG™ coupling detail
Coupling detail.
JACKSTRONG™ spigot end
Spigot end.
JACKSTRONG™ coupling end
Coupling end.
JACKSTRONG™ intermediate jacking station
Intermediate jacking station.
JACKSTRONG™ intermediate jacking station detail
Intermediate jacking station detail.
JACKSTRONG™ pipe storage
Pipe storage.
JACKSTRONG™ pipe yard
Pipe yard.
JACKSTRONG™ pipe transport
Loaded for transport.

Frequently Asked Questions

Common questions on
JACKSTRONG™

The range supplied by Empire covers DN900 to DN3000. Contact Empire’s technical team to confirm availability for your required diameter.
JACKSTRONG™ combines the structural strength of Bonna reinforced concrete with the corrosion resistance of BOSSPIPE™ Glass Reinforced Plastic, as a composite pipe.
JACKSTRONG™ is engineered for pipe jacking and microtunnelling applications, and delivers high jacking load capacity for long drive performance.
Yes. Intermediate jacking station units are available to suit drive length and jacking loads. Contact Empire’s technical team with your drive parameters.
Submit your product, diameter, quantity and project location through the Empire RFQ tool. Empire’s team typically responds within one business day.

Quotes & Proposals

Lock in your jacking pipe supply.

Tell Empire your product, diameter, quantity and location, and the team will respond with a quote. Typically within one business day.